HD: Operators & Admins Manual

This manual is about running an instance. Installing one is install/ADMIN_GUIDE.md, which covers host requirements, sizing, the cluster definition, and the Ansible and Kubernetes paths. The invariants below — the cpuset split, the core counts — are the ones the installer enforces, so a deployment it produced already satisfies them.

HD is a high-performance, strictly segmented Data Management System built for massive-scale analytics and isolated tenancy. It heavily leverages C++ native processing (DuckDB, DPDK, NORM multicast) paired with Go-based control planes (DMS-Core, Proxy) for orchestration.

High-Level Architecture

The system uses three distinct planes isolated at the network level:

  1. Control Plane (Port 6986): Over-the-wire HTTPS mTLS APIs for node registration, policy distribution, and query telemetry orchestration. Records never pass through this network.
  2. Data Plane (Port 6987): Unidirectional, ultra-fast binary streaming using the FermiHDI HD Wire Protocol (FHDWP). Data flows natively from Storage Nodes back to the requestor over TCP.
  3. Internal DMS / CA Plane (Port 6985 / 6989): Secure channels exclusively connecting the Datastore Management System components to bootstrap new nodes and provision PKI identities.

Core Component Lifecycles

Datastore Management System (DMS)

The DMS is the single source of truth for the HD Instance.

HD Proxy (Query Gateways)

Acts as the ingress gateway for the Control Plane.

Storage Cluster Controllers (SCC)

SCCs orchestrate queries across their domain.

Storage Nodes (SN)

The raw engine layer, executing the native C++ retrieval pipelines.

BloomRF Filter Node (optional)

An SN-shaped engine role that keeps a filter per batch instead of the records, so the SCC can leave batches unread.

Message Bus Ingester

Reads one source — a Kafka, RabbitMQ or MQTT broker, or files from a directory or an S3-compatible store — and streams batches to an SCC.

Query services

hd_sql, hd_graphql, hd_ipflow_graphql and hd_mcp are stateless services outside the storage cluster.

Query Result Return Path

Query results do not travel back the way the query came. The SN opens a new outbound FHDWP connection to a target the caller nominated, so that target must be an address the SN can reach and a port something is listening on. Getting this wrong fails silently: the query is accepted, the SN streams to an address nobody is listening on, and the caller simply waits.

How the target is chosen

Every query carries a required target array (schemas/hd_query_schema.json), and each entry pairs an address with a required port_number. There is no default in the schema — the caller must state one.

The Proxy fills the gap for callers that omit it, in this order:

  1. the caller's own target_dps[0].port_number, validated 1–65535;
  2. the X-Data-Return-Port request header;
  3. 6987, the FHDWP data-plane port.

The SN uses target_dps[0] only. The schema models target as an array, which reads like fan-out to several destinations; the SN streams to the first entry and ignores the rest.

Configuring it on the query services

hd_mcp, hd_graphql and hd_ipflow_graphql each issue queries and listen for the results themselves, so they advertise their own address:

Variable Default Purpose
FERMIHDI_DATA_RETURN_HOST (discovery, then hostname) Address advertised to SNs. Set it when discovery cannot pick the right interface.
FERMIHDI_DATA_RETURN_PORT 6987 Port advertised to SNs, and the port the service listens on. Out-of-range or unparseable values fall back to the default silently.
FERMIHDI_DATA_PLANE_SUBNET 10.150.0.0/24 CIDR used to pick the data-plane interface when the host is not set explicitly.

Resolution order for the host is: FERMIHDI_DATA_RETURN_HOST if set, otherwise the first local interface address inside FERMIHDI_DATA_PLANE_SUBNET, otherwise the container hostname. Discovery exists because DNS is unreliable across multiple container networks — a service name can resolve to the front-end network rather than the data plane — but an explicit host always wins over it.

Version note. Before 2.0.3, hd_mcp and hd_graphql ran subnet discovery unconditionally and overwrote FERMIHDI_DATA_RETURN_HOST, so on any host with an address in the data-plane subnet the variable silently did nothing. Only hd_ipflow_graphql honoured it. If you are on an earlier build and the setting appears to be ignored, that is why; steer the choice with FERMIHDI_DATA_PLANE_SUBNET instead, or upgrade.

Operating Principles

Certificate lifecycle and rules

Every process in an HD instance holds a certificate the DMS-CA signed, and every one of them renews it without a restart. The rules:

Container Deployment Model

All HD components (Storage Node, Storage Cluster Controller, HD Proxy, Message Bus Ingester, and DMS components) must always be deployed as containers, even when running as the only workload on a dedicated bare-metal server. This is a deliberate design principle to align with modern data-centre management practices and orchestration systems (Docker Compose, Kubernetes, Canonical Juju, etc.).

DPDK / SPDK Components: cpuset Split Invariant

Components that use kernel-bypass hardware (Storage Nodes and Storage Cluster Controllers with DPDK networking or SPDK storage) have an additional operational invariant that must be followed on every deployment:

The container cpuset and the MASTER_CPUSET environment variable must reference disjoint sets of CPUs. DPDK-pinned cores must never appear in the container cpuset.

Why this matters: The container runtime shim (containerd-shim on Docker, CRI-O shim on Kubernetes) runs in the host scheduler but inherits the container's cpuset cgroup. If a DPDK core appears in the container cpuset, the shim will be scheduled on that core, evicting DPDK poll-mode threads. This was measured at over 300,000 shim evictions per 90-second window in HD profiling — sufficient to cause measurable write-path latency spikes and query P99 regressions. The isolcpus kernel parameter alone does not prevent this, because an explicit cgroup cpuset assignment overrides isolcpus.

Correct split:

Field Must contain
cpuset (Docker Compose / K8s pod spec) Overflow / management core(s) only
MASTER_CPUSET (env var) All DPDK/SPDK-pinned cores — excluded from cpuset

See hd_sn/docs/user_guide.md — Step 3a for full examples, profiling evidence, and Kubernetes guidance.

Deployment Planning: CPU Core Count Requirements

Use the following table when sizing a host for a HD Storage Cluster. All figures are logical CPU (thread) counts, based on profiling data from RC12 benchmark runs. These figures assume SMT (Hyper-Threading) is enabled.

Role DPDK Cores (MASTER_CPUSET) Overflow Cores (cpuset) Isolation requirement
Storage Node (SN) 10 minimum (8 with SHARE_KV_WITH_STORAGE) 2 Overflow must be on a different physical core from DPDK cores
Storage Cluster Controller (SCC) 6 minimum (7 + N_SNs recommended) 1 SMT sibling acceptable on space-constrained hosts (see note below)
Query Proxy (HD Proxy) 1–2 1 No strict isolation — proxy is not DPDK-intensive

The SN figure is a hard floor, not a recommendation. MASTER_CPUSET is divided between five buckets — transport, storage, filter, hash and kv — each with a floor of 2 logical CPUs. Below 10 (or 8 when SHARE_KV_WITH_STORAGE=true lets kv alias storage) FermiController::Init() throws and the Storage Node does not start. Surplus above the floor is weighted, with the filter taking the largest share: at a MASTER_CPUSET of 28 the split is transport 5, storage 5, filter 10, hash 4, kv 4. See tests/sandbox_dms/sn_resource_recommendations.md, which is the source of truth for this.

Production sizing formula. Once above the floor, size from the workload rather than the minimum: 6 + (3 × active_drives) cores per SN and 7 + N_SNs cores for the SCC. tests/sandbox_dms/fermihdi_sizing.py computes it. The sandbox's own auto-allocation is deliberately more generous again and is not a production guide.

Minimum host sizes for a single Storage Cluster (1 SCC + 3 SNs):

Scenario Logical CPUs
Absolute floor, SHARE_KV_WITH_STORAGE=true 36 — OS 2 + SCC 10 + 3 × 8
Absolute floor, kv on its own cores 42 — OS 2 + SCC 10 + 3 × 10
Production, sized from the formula above 46+
Production recommended (per-SN NUMA isolation) 46+ across two NUMA sockets

These are floors, not targets: a host sized exactly to one runs every bucket at its 2-core minimum with no surplus to weight. An earlier version of this table gave 16 logical CPUs for 1 SCC + 3 SNs, which cannot start — three SNs alone need 30 at the floor.

Fewer Storage Nodes fit a smaller host. The floor is per-SN, so 1 SCC + 1 SN needs 20 logical CPUs (2 + 8 + 10), and 1 SCC + 2 SNs needs 30. A host that cannot meet the per-service minimum falls back to a shared pool, where every service's cpuset is the whole available set and the SN's auto_distribute picks its threads from it.

SCC on fully-allocated hosts: When no spare physical core is available for a dedicated SCC overflow (as in the 16-CPU sandbox), the SCC may safely operate with cpuset == MASTER_CPUSET. The SCC reader thread is not a DPDK PMD spin-poller; it blocks between batches. Profiling shows the resulting scheduler events on SCC DPDK cores are swapper idle handoffs, not active preemption. This is benign. On hosts with ≥ 18 logical CPUs, allocate a dedicated overflow core to the SCC.

Disaster Recovery & Troubleshooting

Node Quarantine

If an SN begins throwing Bad Batch Notice (BBN) Control Messages, quarantine the node via the WebUX. The SCC will dynamically re-route queries to healthy replicas within the Storage Cluster.

A filter node that excludes nothing

Check the SCC's bloomrf_lookup log line for the query. mode: off means the SCC's data plane started before the filter node was ready or the deployment record names off: restart the SCC once the node reports ready. no_filter equal to candidates means the node holds no verified filter for the window — it started after those batches, evicted them, or its verification stream to the SCC is down (fermihdi_bloomrf_filters_pending climbing). A workload whose predicates fall on the batch-id column, use !=, or name values present in every batch is not a fault.

Ingest that never starts on a cluster with a filter node provisioned

The DMS holds the SCC's relay list until every provisioned Storage Node and filter node in the cluster reports ready. Start the filter node, or decommission it in the DMS; do not leave a provisioned node unrun.

Re-establishing Data Plane Sync

If an SN falls behind due to network partition on the NORM interface (UDP 6988), reboot the SN. The SCC will trigger a cold-boot sync event over standard TCP fallback on the Control Plane to ensure data integrity before marking the node Ready.